15 Series Photo Ionizer
VSH-15G/VSC-15G
A high-performance photo ionizer
using a
CNT X-ray tube (world's first)
and capable of
high output and
a high degree of speed control.
using a
CNT X-ray tube (world's first)
and capable of
high output and
a high degree of speed control.
A photo ionizer equipped with a CNT X-ray tube (world's first),
it is capable of high
output and a high degree of speed control.
It is suitable when a high static elimination
capacity
is required in a large area.
In addition, it allows the operator
to connect it with a
PC to identify ON/OFF, operation time of tube, failure, etc.
Features
-
Head
- Equipped with CNT X-ray tube for high output and high speed control
- It can remove static electricity from distant objects over a large area
-
Controller
- Displays operation hours of the head
- Can be connected to external devices using RS-485 communication (Remote Control)
- Up to 4 head units can be connected
- Perfect ion balance
- Free of foreign substances
- Maintenance free
- Fast static elimination
- Ozone free
Application
- Semiconductors When processing wafers and dies
-
Film Separation/Wounding/
Transfer section - Display Return (transfer) section
- Plastic Injection/Parts/Materials Feeding
- Pharmaceutical powder packing
- Inside the facility Rubbing machine, exposure machine, etc.
Specification
VSH-15G / VSC-15G Product Specifications
Product | Item | Content |
---|---|---|
Common | Operating temperature | 0~40℃ |
Storage temperature | -10℃~60℃ | |
Operating humidity | Within 60% | |
Storage humidity | Within 85% | |
HEAD (VSH-15G) |
Tube voltage (DC) | 15 kV |
Angle of irradiation | 150º | |
Power input | DC +24 V | |
MAX power consumption | 38 W | |
Weight | 0.4 kg | |
CONTROLLER (VSC-15G) |
Power input | AC 100~240 V, 50/60 Hz |
MAX power consumption | 70 W | |
Weight | 0.65 kg | |
I/O Interface | Remote, Interlock, Fail | |
Communications | RS-485 | |
I/O Pin Connector | DSUB25P Female |
Decay Time Rate
* Static electricity elimination performance is indicated by the time it takes for a metal plate charged at ±1000 V to drop to ±100 V after being irradiated with Soft X-Ray.Shielding Methods
Material | Shielding thickness (mm) |
---|---|
Stainless steel | 0.5 |
Aluminum | 9 |
Glass | 17 |
PVC | 14 |
Acrylic | 148 |
* After shielding, the measured external radiation dose must be within the legal limit (10 μSv/h).
Dimensions(mm)
-
Head (VSH-15G)
-
Controller (VSC-15G)
Components
Components
-
Head (VSH-15G) / max. 1ea
-
Controller (VSC-15G) / 1ea
-
Output Cable (20m) / 1ea
-
D-Sub Signal Cable 25pin
(5m) / 1ea
Part #: D-15P-0005 -
Fixing Bolt
M4 X 0.7pitch X 10L / max. 8ea -
Power Cable (1.8m) / 1ea