10 Series Photo Ionizer
VSH-10ED/VSC-104ED Double head integrated type
Enhanced maintenance convenience due to
long replacement schedule
※ Be sure to install the head in a shielded facility.
long replacement schedule
The dual head type automatically operates head2
when an event
such as an operation failure error occurs,
reducing replacement
time and
guaranteeing
a continuous production line.
It can be installed in narrow and confined spaces
as it does not
generate ozone. By linking with a PC,
all functions such as ON/OFF,
tube usage time, and fail can be identified.
※ Be sure to install the head in a shielded facility.
Features
-
Head
- The dual head type automatically operates head2 when an event such as an operation failure error occurs, reducing replacement time and guaranteeing a continuous production line.
- Neutralizes static electricity from distant objects
- Warranty: 20,000 hours (10,000 hours per HEAD)
-
Controller
- Displays operation hours of the head
- Can be connected to external devices using RS-485 communication (Remote Control)
- Up to 4 head units can be connected
- Perfect ion balance
- Free of foreign substances
- Maintenance free
- Fast static elimination
- Ozone free
Application
- Semiconductors When processing wafers and dies
-
Film Separation/Wounding/
Transfer section - Display Return (transfer) section
- Plastic Injection/Parts/Materials Feeding
- Pharmaceutical powder packing
- Inside the facility Rubbing machine, exposure machine, etc.
Specification
VSH-10ED / VSC-104ED Product Specifications
Product | Item | Content |
---|---|---|
Common | Operating temperature | 0~40℃ |
Storage temperature | -10℃~60℃ | |
Operating humidity | Within 60% | |
Storage humidity | Within 85% | |
HEAD (VSH-10ED) |
Tube voltage (DC) | 11 kV |
Angle of irradiation | 150º | |
Power input | DC +12 V | |
MAX power consumption | 8 W | |
Weight | 0.64 kg | |
CONTROLLER (VSC-104ED) |
Power input | AC 100~240 V, 50/60 Hz |
MAX power consumption | 56 W | |
Weight | 0.74 kg | |
I/O Interface | Power, Interlock, Fail, Overtime | |
Communications | RS-485 | |
I/O Pin Connector | DSUB 25P Female |
Decay Time Rate
* Static electricity elimination performance is indicated by the time it takes for a metal plate charged at ±1000 V to drop to ±100 V after being irradiated with Soft X-Ray.Shielding Methods
Material | Shielding thickness (mm) |
---|---|
Stainless steel | 0.2 |
Aluminum | 3 |
Glass | 5 |
PVC | 4 |
Acrylic | 46 |
* After shielding, the measured external radiation dose must be within the legal limit (10 μSv/h).
Dimensions(mm)
-
Head (VSH-10ED)
-
Controller (VSC-104ED)
Components
Components
-
Head (VSH-10ED) / max. 4ea
-
1:4 Controller (VSC-104ED) / 1ea
-
Output Cable (15m) / max. 4ea
Part# : E-OC-0015 -
Signal Cable /
D-Sub male Cable 25pin
5m / 1ea
Part #: D-25P-0005 -
Fixing Bolt
1/4”-20UNC X 15L / max 4ea
1/4”-20UNC X 15LX 8L / max 4ea
M4 x 0.7pitch x 10L / max 8ea -
Power Cable (1.8m) / 1ea