05 Series Photo Ionizer

VSN-05UE Head+Controller integrated type

Exempted from radiation
license and reporting obligations!

This has an all-in-one structure that enables easy use,
and operates
with a low voltage of 5 kV. It is a model that
can replace tubes for lower maintenance costs,

and is exempted from reporting obligations in
accordance with the Nuclear Safety Act.

Features

    • Static neutralizer using soft X-ray
    • A miniature head not restricted by installation space
    • Static neutralizer for nearby targets
    • Exempted from radiation license and reporting obligations (in Korea)
    • Integrated and detachable tubes (VSH-05US) are fully replaceable
    • Can check time with a time reader (Optional)
  • Perfect ion balance
  • Free of foreign substances
  • Maintenance free
  • Fast static elimination
  • Ozone free

Application

  • Semiconductors When processing wafers and dies
  • Film Separation/Wounding/
    Transfer section
  • Display Return (transfer) section
  • Plastic Injection/Parts/Materials Feeding
  • Pharmaceutical powder packing 
  • Inside the facility Rubbing machine, exposure machine, etc.

Specification

VSH-05UE Product Specifications

Product Item Content
HEAD
(VSH-05UE)
Tube voltage(DC) 4.98 kV
Irradiation angle 150º
Power input DC +12 V(Adaptor)
MAX power consumption 8 W
Weight 0.4 kg
Operating temperature 0~40℃
Storage temperature -10℃~60℃
Operating humidity Within 60%
Storage humidity Within 85%
Warranty 1 year
Options Time Reader / 1ea
* Design and product specifications are subject to change without notice to improve quality.

Decay Time Rate

* Static electricity elimination performance is indicated by the time it takes for a metal plate charged at ±1000 V to drop to ±100 V after being irradiated with Soft X-Ray.

Shielding Methods

Material Shielding thickness (mm)
Stainless steel 0.2
Aluminum 0.4
Glass 0.7
PVC 0.6
Acrylic 8
* The above shield thickness is based on when the shield is 10 cm away from the radiation source. If the shield is closer to the radiation source, its thickness must be increased.
* After shielding, the measured external radiation dose must be within the legal limit (10 μSv/h).

Dimensions(mm)

  • Head (VSH-05UE)

  • Time reader (optional)

Components

Components

  • Head (VSH-05UE) / 1ea
  • Adapter (DC 12V 3.3A ) / 1ea
    Part #: P-AD12-001
  • Data Cable (5m) / 1ea
    Part #: UE-DC-0015
  • Extension Power Cable
    (15m) / 1ea
    Part #: EX-PC-0015
  • Fixing Bolt
    1/4”X 15L / 1ea
    1/4 X 8L /1ea
    M4 x 0.7pitch x 10L / 2ea
  • Power Cable (1m~1.5m) / 1ea
    AC 220V, 50/60Hz, 1.8m / 1ea
    Part #: PC-220-0018

Download
Catalogs and manuals are available.